Can I use the program created with PE-Expert 3 in PE-Expert 4?
Answer
There is compatibility at the C language level, but since PEOS is not compatible,
It is necessary to replace it with one corresponding to PE-Expert 4.
Also, as a purpose to support conversion, source code converter is available.
As for the code converter, it is necessary to operate on the command prompt.
For Windows 7
1.Copy the mwcsc.exe and default.cnv files in the installation folder to the folder containing the C files you want to convert.
2. Open the command prompt with an accessory, command prompt from all programs.
3. At the command prompt, change to the folder where the .C file is located.
4.2.4 Execute with reference to the execution example.
For details, refer to the C source code converter manual.
<< QA with many inquiries when converting >>
1. With respect to PEV_inverter_set_uvw (BDN, u, v, w, 0); in PE-Expert 3,
It worked even if -2 or more values were entered, but in PE-Expert 4,
-2 <= u, v, w <= 2 Please use.
2. The initialization function of AD, PEV_ad_set_mode (INT 32 bdn, INT 32 mode)
Since it is not often set, please confirm.
For details, refer to Function Reference Manual.